The 12V / 48V contactor is mainly used to control switching on/off of power supply of storage battery car, electric forklift, electric winch, electric car, excavator, air conditioner in vehicle.
InquiryApplication
JX50DT/12V DC Contactor is designed and manufactured through precise calculation and rigorous testing to ensure that it can work properly in various harsh environments. In modern industrial systems, the role of high-voltage DC contactors can not be ignored.
Ordering Notice
For example: JX50DT/12V
The DC contactor of main contact is NO, special installation method, rated voltage not more than
Basic Technical Parameters (at normal conditions) | |||
Electric Parameters | |||
Contact type | NO of Bridge type | Pickup time(ms) | ≤30 |
Rated voltage of contacts (DC) | ≤72V | Release time(ms) | ≤50 |
Rated current of contacts (A) | 50 | Insulation resistance(MΩ) | ≥100 |
Voltage drop on contacts(mV) | ≤100 | Dielectric withstand voltage | 500V,p.f. 1min, no breakdown |
Contact load characteristics | 10A, DC 100V | Electric cycles (104) | ≥2 |
12A, DC 96V | Mechanical cycles (104) | ≥30 | |
20A, DC 80V | Temperature rise on outgoing terminal | ≤65 | |
Contact contact resistance (mΩ) | ≤5 | Temperature rise of coil(K) | ≤85 |
Coil voltage specification(DC) | 12V, 24V, 48V, 72V etc | Insulation grade of enameled wire | Class B (130°C) |
DC power consumption of coil (W) | ≤5.5 | Material of contact | AgCuO(10)/Cu |
Pickup voltage(DC) | ≤70%Us | Working duty | Continuous operating duty |
Release voltage(DC) | ≥5%Us;≤40%Us | ||
Mechanical/Ambient Conditions | |||
Torque of outgoing terminal on contact M8(N.m) |
≯2.5N appropriate | Protection grade | IP54 |
Coil lead-out method | Multi-strand silver plated soft copper insulated wire |
Mounting methods | Freely |
Working temperature | (-25~+55)°C | Vibration | Sine shock: 2.5g, (5~50) Hz |
Mounting altitude | ≤2Km | Impact | 50g,11ms(Half sine) |
Outline and Mounting Picture