Company Profile
Zhejiang Nanfeng Electric Co.,Ltd. is a company.With DC contactor as the leading factor, it integrates production, R & D, manufacturing anAn enterprise that can be integrated. Our company is specialized in producing medium load and heavy load DC contactor is suitable for electric forklifts, battery cars, tractors, and excavating. Machine, automobile air conditioner, communication power supply, uninterrupted power supply, electroplating power supply, etc. system The switch control of the integrated electronic control circuit has the advantages of small volume and large load capacity. Long service life, simple maintenance, wide application range, and well received by users. Welcome.
TEL: +86-577-62797256 62776658
FAX:+86-577-62797257
EMAIL:king@kingnan.com
product description
Ordering Notice
- For example: ZJW100-22S/12V
- The DC contactor of main contact is 2NO+2NC, with micro switch, vertical installation, rated voltage not more than DC80V, current 100A, coil voltage is
Technical Parameters
Contact type | 2 NO+2NC of bridge type | Instantaneous maxi (closing) current | 7Ie,≤1s |
Rated voltage of contacts (DC) | DC: 80V; AC: 380V | Insulation resistance(MΩ) | ≥100 |
Rated current of contacts (A) | DC: 100; AC: 30 | Dielectric withstand voltage | 2500V,p.f. 1min, no breakdown |
Voltage drop on contacts(mV) | ≤80(at 100A) | Electric cycles (104) | ≥2 |
Coil voltage specification(DC) | 6~220V | Mechanical cycles (104) | ≥30 |
DC power consumption of coil (W) | ≤27 | Temperature rise on outgoing terminal | ≤65 |
Pickup voltage(DC) | ≤70%Ue | Temperature rise of coil(K) | ≤85 |
Release voltage(DC) | ≥5%Ue;≤40%Ue | Insulation grade of enameled wire | Class B (130°C) |
Pickup time(ms) | ≤30 | Material of contact | AgCuO(10)/Cu |
Release time(ms) | ≤50 | Working duty | Continuous operating duty |
Outline and Mounting Picture
Ordering Notice
- For example: ZJW100-20S/12V
- The DC contactor of main contact is 2NO, with micro switch, vertical installation, rated voltage not more than DC80V, current 100A, coil voltage is
Technical Parameters
Contact type | 2 NO of bridge type | Instantaneous maxi (closing) current | 7Ie,≤1s |
Rated voltage of contacts (DC) | DC: 80V; AC: 380V | Insulation resistance(MΩ) | ≥100 |
Rated current of contacts (A) | DC: 100; AC: 30 | Dielectric withstand voltage | 2500V,p.f. 1min, no breakdown |
Voltage drop on contacts(mV) | ≤80(at 100A) | Electric cycles (104) | ≥2 |
Coil voltage specification(DC) | 6~220V | Mechanical cycles (104) | ≥30 |
DC power consumption of coil (W) | ≤15 | Temperature rise on outgoing terminal | ≤65 |
Pickup voltage(DC) | ≤70%Ue | Temperature rise of coil(K) | ≤85 |
Release voltage(DC) | ≥5%Ue;≤40%Ue | Insulation grade of enameled wire | Class B (130°C) |
Pickup time(ms) | ≤30 | Material of contact | AgCuO(10)/Cu |
Release time(ms) | ≤50 | Working duty | Continuous operating duty |
Outline and Mounting Picture