China Nanfeng Electric
86-577-62797256 king@kingnan.com
ZJW100-30 DC Contactor

ZJW100-30 DC Contactor

Application The product is mainly used in the EPS power supply of the communication base station, and the contacts can also be used for AC

  • ZJW100-30 DC Contactor
ONLINE SERVICE

TEL:+86-577-62797256 62776658

FAX:+86-577-62797257

EMAIL:king@kingnan.com

Inquiry

Application

ZJW100-30 DC Contactor 100A adopts arc suppression technology such as magnetic blowing or arc extinguishing chamber, which can effectively extinguish the arc when the contacts are disconnected, prevent damage, and extend the service life of the contactor.

Ordering Notice

For example: ZJW100-30S/12V
The DC contactor of main contact is 3NO, with micro switch, vertical installation, rated voltage not more than DC80V, current 100A, coil voltage is

Basic Technical Parameters (at normal conditions)
Electric Parameters
Contact type 3 NO of bridge type Instantaneous maxi (closing) current 7Ie,≤1s
Rated voltage of contacts (DC) DC: 80V; AC: 380V Insulation resistance(MΩ) ≥100
Rated current of contacts (A) DC: 100; AC: 30 Dielectric withstand voltage 2500V,p.f. 1min, no breakdown
Voltage drop on contacts(mV) ≤80(at 100A) Electric cycles (104) ≥2
Coil voltage specification(DC) 6~220V Mechanical cycles (104) ≥30
DC power consumption of coil (W) ≤20 Temperature rise on outgoing terminal ≤65
Pickup voltage(DC) ≤70%Ue Temperature rise of coil(K) ≤85
Release voltage(DC) ≥5%Us;≤40%Us Insulation grade of enameled wire Class B (130°C)
Pickup time(ms) ≤30 Material of contact AgCuO(10)/Cu
Release time(ms) ≤50 Working duty Continuous operating duty
Magnetic Retention Structure Supplementary Parameter
Contact initial state NO Control power supply characteristics Positive and reverse pulse power supply
Contact action characteristics Coil plus positive pulse contact closure Power pulse time 200ms≤t≤1s
Coil plus reverse pulse contact disconnect Pickup voltage(DC) ≤75%Ue
Instantaneous power 
consumption of the coil
≤48.0(W) Release voltage(DC) ≤75%Ue
Mechanical/Ambient Conditions
Torque of outgoing terminal 
on contact M6(N.m)
≯4.5N appropriate Protection grade IP50
Coil wiring insert(mm) 0.8 Mounting methods Freely
Working temperature (-25~+55)°C Vibration Sine shock: 2.5g, (5~50) Hz
Mounting altitude ≤2Km Impact 50g,11ms(Half sine)

Outline and Mounting Picture

Basic size (mm) Tolerance size (mm)
0~30 ±0.2
30~60 ±0.3
60~100 ±0.5
>100 ±0.1

 

Mini Circuit Breaker
Related Products
ZJW100-03 DC Contactor
ZJW100-03 DC Contactor

Application The product is mainly used in the EPS power supply of the

ZJW100-33 DC Contactor
ZJW100-33 DC Contactor

The coil of the 12V DC reversing contactor produced by the DC contacto

ZJW100-22 DC Contactor
ZJW100-22 DC Contactor

The product is mainly used in the EPS power supply of the communicatio

ZJW100-02 DC Contactor
ZJW100-02 DC Contactor

The product is mainly used in the EPS power supply of the communicatio

GET A QUOTE

king@kingnan.com

GET IN TOUCH NOW
×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All